Fumasep FAA-3-PK-130 Anion Exchange Membrane 100mm x 100mm

SKU: DEKEA511EA

Special Price NZ$155.95

Regular Price: NZ$194.95

Description

• Fits all major brands of potentiostats
• 30 Days Return guaranteed
• Size: 100*100mm

The Fumasep FAA-3-PK-130 is a PK (polyketone) reinforced anion exchange membrane that features low resistance, high selectivity, and excellent mechanical stability, performing reliably in both acidic and alkaline environments. With a thickness of 130 µm, it’s the thickest model in the FAA-3 series, designed for tough electrochemical applications that demand extremely high mechanical durability and very low proton crossover.

Our Recommendations

Product Details

FAA-3-PK-130 is widely used in various alkaline electrochemical systems, and it performs especially well in situations where the stability of the membrane material is crucial:

characteristic:

Electrochemical carbon dioxide reduction (CO₂RR): this is one of its main applications.

Alkaline fuel cells (AFC) and alkaline water electrolysis (AEMWE).

Flow batteries, especially organic flow batteries.

Processes like electrodialysis, desalination, deionization, and acid recovery.

Specification:
Model: FAA-3-PK-130
Size: 100mm x 100mm
Thickness: 130um
Appearance/Color: Brown
Backing Foil: None
Delivery Form: Dry
Reinforcement: PK
Counter Ion:Bromide (Br-)
Density: 10 - 13 mg•cm-2
Specific Area Resistance: 1.8 - 4.0 (in Cl- form) Ω•cm2
Specific Conductivity: 4.0 - 8.0 (in Cl- form) mS•cm-1
Selectivity: 93 - 98 %
Proton Transfer Rate: 800 - 2500 µmol•min-1•cm-2
Ion Exchange Capacity: 1.1 - 1.4 (in Cl- form) meq•g-1
Dimensional Swelling in H2O at 25°C: 0 - 2 %
Uptake in H2O at 25°C : 10 - 25 wt %
Non-Std Modulus (MPa): 1000 - 1800 MPa
Tensile Strength - max. (MPa): 40 - 80 MPa
Yield Strength at 23°C/50 % R.H.: 20 - 30 MPa
Elongation to Break (%): 15 - 40 %
pH Stability Range at 25°C: 0 - 14 pH
Bubble Point Test in Water at 25°C: >3 bar

Storage:

Dry Form: The membrane can be stored dry for an unlimited amount of time. However, the membrane has to be conditioned (washed and rinsed) prior to use.

Wet Form: Storage for short and medium time scale (hours up to several weeks) may be done in unsealed containers in 0.5 - 1.5 wt% NaCl solution or comparable neutral pH electrolytes. For storage over a longer time period a sealed container is recommended using afore said electrolyte with ca. 100 ppm biocide (NaN3) to avoid biological fouling.

Pre-Treatment and Conditioning:

The membrane is delivered in bromide form and dry form. Depending on application and cell design, assembling is possible in dry (without pretreatment) or wet form. Before assembling in wet form put the membrane sample between stabilizing meshes / spacers (in order to avoid curling) in NaCl solution - e.g. 0.5 M NaCl solution at 25°C for 72 hours exchanging the solution several times. Do not let the membrane dry out since micro-cracks may likely occur during shrinkage.

NOTICE:
1. Keep membrane package closed / sealed when unused. Unpack membrane only for direct use and process immediately after opening. Store, handle and process the membrane in a clean and dust-free area.
2. Always wear protective gloves when handling the membrane. Handle with care, be sure not to puncture, crease or scratch the membrane, otherwise leaks will occur. All surfaces which may get into contact with the membrane during inspection, storage, pretreatment and mounting must be free of sharp edges or angles.

Product Includes:
1 * Fumasep FAA-3-PK-130 Anion Exchange Membrane 100mm x 100mm

NEED HELP? CONTACT US

Call Toll-Free +1 (800) 972-7086

Email Us:

    Shipping
  • Standard Shipping: 5-7 Business days
  • DHL/Fedex Express Shipping: 2-5 Business days

PAYMENT

PRODUCT SHOW

We devotes itself to providing laboratory instrumentation that enables simultaneous in-situ measurements of a number of signals (electrochemical, optical, thermal and other) on thin film and membrane materials. we have already gained so much experience in the field of electrochemical trading and our final goal is to offer our customers various kinds of laboratory instrumentation and at best price. We are gradually becoming one of the top instrumentation online shop throughout the world and we do hope we could make you outstanding by providing the real good stuff you want. Enjoy your shopping with us and have a nice day.

Document#
Title
Type
Download
None Document is available.
if you need customization help, pls contact us via: here

PRODUCT RELATED

Q.
How to choose ordinary electrochemical cell and sealed electrochemical cell?
A.
Regardless of the user's tightness requirements for the actual test, the sealed electrochemical cell is the first choice. The sealed electrolytic cell is equipped with hollow sealing screws and fluorine rubber O-rings to install and seal the entire device, and then pass inert gas into the cell body to drive out the excess gas inside the cell body to realize the test of the system in an inert environment. If there is no requirement for tightness, no ventilation operation is required. However, if you choose an ordinary electrochemical cell, the related operations of the sealed electrolytic cell cannot be realized.
Q.
What volume of electrochemical cell is suitable to choose?
A.
The volume of the electrolytic cell should be selected moderately. If the volume is too large, the amount of solution will be too much, which is unnecessary. During electrochemical measurement, the electrode surface undergoes oxidation and reduction reactions, and some substances in the solution are reduced by participating in the electrode reaction. At the same time, some reaction products will dissolve into the solution. If the volume of the electrolytic cell is too small, the solution concentration will change significantly during the long-term steady-state measurement, which will eventually affect the experimental results. In most cases, the volume of 50ml and 100ml are more choices.
Q.
How to choose a working electrode?
A.
Common working electrodes include disk electrodes and replaceable electrode holders. The disk electrode is suitable as the base of the modified material, and it is modified to the base area of the disk electrode by mixing a membrane solution or the like with a powdered material. And if the material being studied is a sheet-like structure or the material can be modified to suitable materials such as conductive glass, carbon paper, carbon cloth, etc., it is more practical to choose a replaceable electrode clip.
Q.
How to choose a counter electrode?
A.
One of the important parameters of the counter electrode is its surface area. The counter electrode must have a large enough area to support the current conduction generated on the working electrode. Generally, the area of the counter electrode is 3-5 times the area of the working electrode. When choosing a disk electrode as the working electrode, platinum wire electrode is a good choice. When choosing sheet materials as working electrodes, platinum wire ring electrodes and platinum sheet electrodes are good choices.
Q.
How to choose a reference electrode?
A.
Generally speaking, calomel electrode or Ag/AgCl reference electrode is used in neutral system. Since the potential of calomel electrode changes greatly with temperature, when the temperature exceeds 70 degrees, it needs to be used with a salt bridge or replaced Use Ag/AgCl reference electrode. Hg2SO4 reference electrodes are generally suitable for sulfuric acid or sulfate systems. Hg/HgO reference electrodes are generally suitable for alkaline electrolyte solutions, of which the strong alkali system also needs to be used with a salt bridge, and the filling liquid in the salt bridge is consistent with the filling liquid of the reference electrode. The non-aqueous organic system needs to use a Ag/Ag+ reference electrode. When using a non-aqueous Ag/Ag+ reference electrode, the user needs to prepare a solution containing supporting electrolyte and silver ions (usually 10mM) and inject it into the reference electrode chamber. Due to shipping safety considerations, all reference electrodes are not filled with solution. Before use, the user needs to prepare an internal solution to fill it into the electrode.
Q.
Do you offer wholesale discounts?
A.
Yes, We have regular promo activities for all our customers. We do offer discounts to our customers who buy in bulk. We are appreciated for your inquire through E-mail. service@dekresearch.com.


SHOPPING GUIDE

Q.
Why the page does not jump during the process of placing order or adding the item to my cart?
A.
When you add the item to your cart or when you place the order, the page may not jump. There are some reasons for this situation. Maybe the speed of the browser you are using is slow, maybe the item you are adding is out of stock or you forget to choose the size of the item. You can change another browser to try, or check if you have selected the size of the item. If you also have problems please feel free to contact the online customer service to ask help, We will be happy to help you.
Q.
Do you have a physical store?
A.
In an effort to keep our prices low, we only do business online at the moment.
Q.
How can I use my coupon code?
A.
Generally it can be used in two ways. One is to fill it straight in "Discount Codes" textbox when you stay in shopping cart page .


ORDER GUIDE

Q.
How can I check my order information?
A.
For your convenience we highly encourage you to remember your order No.and provide it to us so that we can answer your any question accordingly. And the order No. is same as the invoice ID.Thank you for your support.
Q.
Why my payment was taken but the status of the order shows Pending?
A.
Generally speaking, after the order payment was completed the status of your order will show Processing, and will not change again till you receive your order. If it shows pending, please contact the customer service via email or online chat to check if your payment has been completed.
Q.
How to make sure that my order is finished?
A.
Once you had placed an order successfully, a confirmed letter including your order information would be provided by system automatically. We are very happy to answer your any questions by E-mail: service@dekresearch.com.

Returns Policy

SHIPPING POLICY
Destinations Delivery Option Cost* FREE SHIPPING Total Time
US
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
UK
Standard Shipping £19.95 on order £159+ 5-7 Businesss Days
Express £24.95 on order £249+ 2-5 Businesss Days
CA
Standard Shipping CA$19.95 on order CA$159+ 5-7 Businesss Days
Express CA$24.95 on order CA$249+ 2-5 Businesss Days
AU
Standard Shipping AU$19.95 on Order AU$159+ 5-7 Businesss Days
Express AU$24.95 on Order AU$249+ 2-5 Businesss Days
DE
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
FR
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
RU
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
MY
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
SG
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
PH
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
NZ
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
JP
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
BR
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
VN
Standard Shipping $19.95 on order $159+ 5-7 Business Days
Express $24.95 on order $249+ 2-5 Businesss Days
    • Fumasep FAA-3-PK-130 Anion Exchange Membrane 100mm x 100mm was successfully added to your shopping cart.